Look
A person inspects moisture, fans, combustion equipment, and obvious sources. This comes before most laboratory samples. You are paying for trained eyes and a written record of what was seen.
A test measures one thing, in one place, for a length of time. It can support a building decision. It cannot diagnose a person, and it cannot promise the building is safe.
“Get the air tested” sounds like one service. It is three different kinds of work. The useful one depends on the question.
A person inspects moisture, fans, combustion equipment, and obvious sources. This comes before most laboratory samples. You are paying for trained eyes and a written record of what was seen.
A meter logs particles, carbon dioxide, humidity, carbon monoxide, or radon for hours or months. The pattern matters. A photo of the screen is a moment, not a log.
Air, dust, or a piece of material goes to a laboratory for a named method. You should receive the lab pages, not only a summary sentence.
“Not detected” means the method did not see that substance above its detection limit. It does not mean zero, and it does not mean safe.
Indoor air changes. Cooking, a shower, a candle, an open window, a crowd, the furnace cycling, and the weather outside all move the numbers. A sample is a snapshot of the place and the minutes or hours it covered.
Guidelines almost always name an averaging time: one hour, eight hours, 24 hours, or a year. A ten-minute reading cannot be laid on top of a 24-hour guideline and called a pass or a fail. Ask which average the report used.
Outdoor standards are another mismatch. Cities have limits for outdoor air, averaged across many days. A kitchen at dinnertime is not that measurement. Workplace limits are for healthy adult workers on a shift. They are not targets for a nursery.
In plain words. A number needs four companions: what was measured, the unit, how long it was measured, and which guideline is being used as a comparison. Without those four, the number is a loose fact.
| Unit | What it means | You will see it on |
|---|---|---|
| ppm | Parts per million. One drop in a million drops. | Carbon dioxide, carbon monoxide, some chemicals |
| ppb | Parts per billion. A thousand times smaller than ppm. | Formaldehyde, nitrogen dioxide |
| µg/m³ | Micrograms in a cubic metre of air. A weight, not a count of “toxins.” | Particles, formaldehyde, many chemicals |
| pCi/L | Picocuries per litre. A radioactivity unit used for radon in the United States. | Radon |
| Bq/m³ | Becquerels per cubic metre. The radon unit used in Canada. About 37 Bq/m³ equals 1 pCi/L. | Radon |
| % RH | Relative humidity. How full the air is of moisture at that temperature. Not a contaminant. | Comfort and mold-risk context |
| CFU or spores/m³ | A count of what grew in a dish, or what was seen under a microscope. Not a health score. | Some mold samples |
PM2.5 means particles smaller than 2.5 micrometers. PM10 means smaller than 10 micrometers. Fine particles come from smoke, cooking, candles, traffic, and some indoor reactions. Larger dust settles on shelves.
A particle monitor counts or estimates the amount in the air while it runs. It does not tell you whether the particles are pollen, smoke, or skin flakes. That naming needs a different method, and even then the mix is messy.
The U.S. EPA’s outdoor standards for PM2.5, strengthened in 2024, are 9.0 micrograms per cubic metre as an annual average and 35 as a 24-hour standard. The World Health Organization’s 2021 outdoor guidelines are tighter still: 5 annual and 15 for 24 hours. These describe community outdoor air. They are a reference some reports borrow. They are not a law that a living room fails because dinner pushed a monitor up for twenty minutes.
What this cannot prove. The source, from one reading. A health effect in a named person. That the air is “clean” because a later reading dropped.
People breathe out carbon dioxide. Outdoor air is a little above 400 parts per million. In a closed room the indoor number climbs. It falls when you bring in fresh air or when people leave.
Health Canada recommends a long-term home limit of 1,000 ppm, based on a 24-hour average. The supporting document says the symptoms in the studies — irritation, tiredness, trouble concentrating — cannot be blamed on carbon dioxide alone with certainty. They may come from poor indoor air in general, with carbon dioxide as the marker. ASHRAE Standard 62.1 does not set 1,000 ppm as a limit. People still repeat that figure as if ASHRAE had. A U.S. workplace 8-hour limit of 5,000 ppm is an occupational rule. It is far above what you want in a home, and it is not a “safe bedroom” line.
In plain words. A high carbon dioxide reading means “this room needs more fresh air for the number of people in it.” It does not mean carbon monoxide poisoning. The gases are different. The alarm on your wall is for carbon monoxide.
What this cannot prove. That the air is free of chemicals, mold, or radon. That a headache is caused by the number on the logger. That a short peak equals the 24-hour average in the Canadian guideline.
Carbon monoxide comes from incomplete burning: a blocked furnace vent, a car in a garage, a generator, a charcoal grill, a gas oven used as a heater. You cannot see it or smell it. It reduces the blood’s ability to carry oxygen. That is why alarms and leaving the building come before any educational page.
Health Canada’s residential guidelines are 25 ppm averaged over one hour, and 10 ppm averaged over 24 hours. The World Health Organization’s indoor guidelines from its selected-pollutants report are in a similar range and also include shorter peaks: about 87 ppm for 15 minutes, about 31 ppm for one hour, about 9 ppm for eight hours, and about 6 ppm for 24 hours. Those are guideposts for limiting exposure. They are not instructions to stay indoors and watch a meter if an alarm is sounding.
Home alarms are designed to sound before a healthy adult would be expected to suffer serious acute harm. They are not laboratory instruments, and they may not sound at the lower guideline levels. A quiet alarm does not prove a 24-hour average is fine. If the alarm sounds, leave.
The United States does not set one federal indoor home limit that matches Health Canada’s pair of numbers. Appliance rules, building codes, and alarm requirements do the practical work. An occupational 8-hour limit (OSHA’s permissible exposure limit is 50 ppm) is a workplace rule. A report that says “under the OSHA limit” has not shown that a home meets a residential guideline.
What this cannot prove. That the furnace is safe, if nobody inspected the vent. That a low afternoon reading describes the night. That symptoms in a person are, or are not, carbon monoxide. That question belongs with emergency care or a clinician.
Gas burners and some other flames release nitrogen dioxide as well as particles and moisture. Health Canada’s residential guidelines are 90 ppb (170 µg/m³) over one hour and 11 ppb (20 µg/m³) over 24 hours. Electric cooking does not make nitrogen dioxide the same way. It still makes particles and moisture, especially frying.
The practical control is a hood that exhausts outdoors, used while the burner is on, plus a window path for makeup air when you can. A recirculating hood mostly catches grease. It does little for the gas.
What this cannot prove. A single nitrogen dioxide reading away from the stove, hours after cooking, does not describe the hour the burner was on. A mold test does not measure this gas.
Volatile organic compounds are gases that evaporate from paints, cleaners, glues, new furniture, flooring, markers, and some combustion. There are hundreds of them. They do not share one health meaning.
“TVOC” means total volatile organic compounds: a lump sum. Cheap sensors do not all count the same chemicals, and there is no Health Canada or U.S. EPA home limit for that lump sum. A low TVOC score does not mean the air is safe. A high score does not name the chemical. Treat a consumer TVOC meter as a rough “something is off-gassing” clue, not as a lab result.
Formaldehyde is one specific chemical, common from some pressed-wood products, glues, and some permanent-press fabrics, and also from combustion including tobacco. It needs a method aimed at formaldehyde, often a sampler left for hours and read by a lab. Health Canada’s residential limits are 100 ppb (123 µg/m³) over one hour, and 40 ppb (50 µg/m³) over eight hours. Below the eight-hour number, Health Canada says adverse effects are not expected. Above it, longer exposure is linked with respiratory symptoms, especially in children. Above the one-hour number, short-term eye, nose, and throat irritation becomes more likely. Those are population guidelines, not a diagnosis for the person in the room.
The controls Health Canada emphasizes are source and ventilation: fewer emitting products, no smoking indoors, fans and outdoor air, and indoor humidity that is not kept damp. The agency suggests around 30% relative humidity in winter and around 50% in summer in its formaldehyde guidance.
What this cannot prove. A complete list of chemicals. A health effect. That a renovation is “non-toxic.” Workplace exposure limits cited on a lab table are for workers, not for the averaging time or the people in a home, unless the report explains that clearly.
Mold testing is several different methods. An air sample may be a spore trap: particles caught on a slide and counted under a microscope, reported as spores per cubic metre. A culture grows what will grow on a dish, reported as colony-forming units. A tape lift from a surface shows what is sitting on that spot. None of these is a medical test.
The U.S. EPA does not set a numerical limit for mold spores in homes. Comparing an indoor count with an outdoor count can help an investigator, and it can also mislead if the outdoor sample was taken in different weather or if the indoor sample was taken while someone was disturbing dust. Species names on a report do not rank “safe mold” and “toxic mold” for a homeowner. Dark growth is not automatically the species people fear, and pale growth is not automatically harmless. Growing mold means a moisture problem.
What this cannot prove. That the home is mold-free. That mold caused symptoms. That a “black mold” line on a lab table is an emergency by itself. Hidden growth is found by looking in the wet place, not by hoping a hallway air sample will find it.
Radon testing is one of the clearest measurements in this field, and it still has limits. The device reports an average for the time it was in place. Radon moves with the weather, the heating system, and how closed the house is. A three-month or longer test is a better stand-in for the year than a weekend.
Before you buy a device, ask your local public-health unit in Canada, or your state radon office in the United States, whether they lend or give a long-term test. Some towns and libraries do. Not every place does, and the offer can end when the kits run out. The U.S. EPA lists state radon offices. Health Canada explains the long-term test. This site does not name brands.
A test you leave in place for months is the usual first result. A plug-in monitor shows the ups and downs from day to day. That pattern helps after you already know the level, or while you check a repair. A few days on a monitor is still a short test.
Use the guideline for the country of the building. Health Canada: 200 Bq/m³. U.S. EPA: fix at 4 pCi/L (about 150 Bq/m³) or higher, and consider fixing between 2 and 4 pCi/L. The EPA estimates the average U.S. home near 1.3 pCi/L and outdoor air near 0.4 pCi/L. There is no known risk-free level. Fixing means a reduction system and a retest, not a second copy of the same bad news.
What this cannot prove. The mold, chemical, or carbon monoxide status of the house. A guarantee that a short test equals the yearly average. A result in the basement storage room, where nobody spends time, is not automatically the result in the bedroom upstairs — test the level where people actually live.
A humidity meter is a reasonable, low-cost tool. Relative humidity around 30 to 50 percent is a practical home range. Keeping it under about 60 percent makes mold growth on surfaces less likely. Very dry winter air can irritate skin and airways and is still not “contaminated air.” Condensation on a winter window means the glass is cold and the indoor air is moist. It is a clue, not proof of mold inside the wall.
Temperature and humidity explain comfort and moisture risk. They are not a test for radon, carbon monoxide, or chemicals.
Allergens such as dust-mite debris, pet dander, and pollen are often handled by cleaning, washing bedding hot, keeping humidity moderate, and using a HEPA cleaner in the bedroom. Air samples for allergens are specialized. A negative sample does not prove the home is allergen-free, and it does not replace allergy care from a clinician.
Asbestos is a fiber in some older building materials. The usual test is of the material that will be disturbed, in a laboratory set up for asbestos, before renovation. A general indoor-air panel does not do this. Intact material that will be left alone is usually left alone.
Lead dust from old paint is checked with dust wipes on floors and window sills, using a method aimed at lead. It is not a mold test and not a VOC test.
A carbon monoxide alarm is safety equipment. Buy one that meets the safety standard named on the package for your country, place it as the instructions say, and replace it when the maker says. It is not a tool for logging small differences against a guideline.
A humidity meter is a reasonable household tool. For radon, start with a long-term test, including one from a local health office if they have one. A plug-in radon monitor is optional and comes later. This site does not name brands. A particle counter can teach you that cooking and candles spike the air. It cannot name the particles.
Avoid ozone generators sold as air cleaners for occupied rooms. Ozone is a lung irritant. Public health agencies have warned that these machines do not safely “purify” a room people are living in. Some ionizers and “plasma” gadgets also make ozone as a by-product. If a product’s claim is that it destroys all mold, all chemicals, and all odours with ozone, that claim is not a reason to run it around children or anyone with asthma.
A laboratory is worth the cost when the question names a substance and a method, and when you will receive the chain of what was collected, how long, and what the lab is accredited to do. Accreditation means the lab has been checked for that method. It does not mean the person in your house chose the right place to sample.
These are comparison points from public agencies. They are not a score for your house, and a short meter reading is not the average named in the row.
| What | Number people quote | What it actually is |
|---|---|---|
| Radon, Canada | 200 Bq/m³ | Health Canada guideline. Take action if the long-term average in a normally occupied area is higher. Not a zero-risk line. |
| Radon, United States | 4 pCi/L (about 150 Bq/m³) | EPA recommends fixing at or above this level, and considering a fix from 2 to 4 pCi/L. Not the same number as Canada’s 200 Bq/m³. |
| Carbon monoxide, Canada | 25 ppm over 1 hour; 10 ppm over 24 hours | Health Canada residential guidelines. A home alarm may not sound at these levels. An alarm that does sound means leave. |
| Carbon monoxide, workplace | 50 ppm over 8 hours (OSHA) | A U.S. workplace rule. Not a home guideline and not a children’s sleeping standard. |
| Carbon dioxide, Canada | 1,000 ppm over 24 hours | Health Canada residential guideline. A clue to stale air. Not proof that carbon dioxide alone is the cause of symptoms, and not a carbon monoxide reading. |
| Carbon dioxide, workplace | 5,000 ppm over 8 hours | Occupational limit. Not a home target. ASHRAE 62.1 does not set 1,000 ppm as a pass/fail. |
| Formaldehyde, Canada | 100 ppb over 1 hour; 40 ppb over 8 hours | Health Canada residential guidelines. A TVOC meter is not this test. |
| Nitrogen dioxide, Canada | 90 ppb over 1 hour; 11 ppb over 24 hours | Health Canada residential guidelines. Relevant to unvented combustion, including gas cooking. |
| PM2.5, outdoor United States | 9.0 µg/m³ annual; 35 µg/m³ over 24 hours | EPA outdoor air standards. Not a pass/fail for a short indoor reading. |
| Mold spores | No federal home limit | EPA has no numerical standard for mold in houses. Visible growth means fix the moisture. |
They may have measured different substances, used different instruments, sampled at different times, or compared the result with different guidelines. Ask for the method, the time, the unit, and the guideline. If those four do not match, the numbers are not a disagreement yet. They are two different tests.
Ask that out loud. Elevated compared with outdoors, with a workplace limit, with a Canadian home guideline, or with the company’s own colour chart are four different claims. A colour chart that is not tied to a named public guideline is marketing.
No. A test can show what it measured, under the conditions of that visit. Health is a medical word. Buildings get new leaks, new furniture, and new seasons.
Reviewed November 2026 for Canada and the United States. This page explains public guidelines. It is not a reading of your report and not medical advice.